APPLICATION INSTRUCTIONS
Lead the cable from the transformer through the pre-cut downlight aperture in the ceiling
Pierce the cable entry point in the top of the cover with a sharp object, creating an opening large enough to suit the cable size
Feed sufficient cable through the opening for the connection
Compress the cover and pass it through the aperture in the ceiling
Open out the cover once inside the ceiling, away from the light fitting
Using the two supplied pins, fasten opposite inner flanges of the cover to the plasterboard
Insert the light fitting and fasten the closing mechanism over the inner flaps of the downlighter cover to seal the opening
Downlighter covers require a minimum of 40mm horizontal clearance and 15mm vertical clearance
Cages are rigid and require no clearance, meaning that insulation can be packed around them as long as it does not cover the ventilation holes
NB: Downlighter cages cannot be compressed to fit through the light fitting aperture from below and must therefore be positioned from above
FIRE TEST PERFORMANCE
Tested to BS476 Parts 22 & 23, achieving up to 240 minutes integrity.
Acoustic properties tested to BS EN ISO 140-3 (63dB).
FOR LOW VOLTAGE DOWNLIGHTERS AND TRANSFORMERS TOGETHER
REGULAR 60 MINUTES ACOUSTIC 60 MINUTES
LENGTH/WIDTH/HEIGHT (mm) LENGTH/WIDTH/HEIGHT (mm)
DSLVA 300 x 100 x 120 DSLVA/AC 320 x 120 x 140
DSLVB 300 x 180 x 140 DSLVB/AC 320 x 200 x 160
DSLVC 300 x 220 x 140 DSLVC/AC 320 x 240 x 160
DSLVD 300 x 300 x 140 DSLVD/AC 320 x 320 x 160
DSLVF 450 x 290 x 150
DSLVG 475 x 320 x 215
DSLVO 400 x 250 x 200 DSLVO/AC 400 x 250 x 200
Other sizes made to order